Publications
Publication: Foot & Ankle Surgery
Date: March 2014
Authors: Bariteau JT, Fantry A, Blankenhorn B, Lareau C, Paller D, Digiovanni CW
Abstract
BACKGROUND:
Supination external rotation (SER) injuries are commonly fixed with a one third tubular neutralization plate. This study investigated if a combination locked plate with additional fixation options was biomechanically superior in osteoporotic bone and comminuted fracture models.
METHODS:
Using an osteoporotic and a comminuted Sawbones model, SER injuries were fixed with a lag screw for simple oblique fibula fractures, and either a one third tubular neutralization plate or a locking plate. Samples were tested in stiffness, peak torque, displacement at failure, and torsion fatigue.
RESULTS:
There was no statistically significant difference in biomechanical testing for fractures treated with a lag screw and plate. For comminuted fractures, locked plating demonstrated statistically significant stiffer fixation.
CONCLUSION:
A combination locked plate is biomechanically superior to a standard one third tubular plate in comminuted SER ankle fractures. There was no biomechanical superiority between locked and one third tubular plates when the fracture was amenable to a lag screw.